AQA A Level Chemistry Required Practicals (RP1–12) — Complete Expert Guide
AQA A Level Chemistry Required Practicals (RP1–RP12)
Why the required practicals matter
All 12 practicals at a glance
| RP | Practical | Core technique | Key measurement | Typical exam question |
|---|---|---|---|---|
| 1 | Making a volumetric solution and an acid–base titration | Weighing by difference, volumetric flask, burette titration | Mass to 2 or 3 d.p., titre to 0.05 cm³ | Why rinse the burette with the solution, why use a white tile, uncertainty in the titre |
| 2 | Measurement of an enthalpy change | Polystyrene cup calorimetry, temperature before and after | Temperature to 0.1 °C or better, mass of solution | Why the enthalpy change is less exothermic than the data book value |
| 3 | Rate of reaction with temperature | Sodium thiosulfate and acid, time to cross disappears | Time to the nearest second, two temperatures | Sketch and explain the rate against temperature graph |
| 4 | Identifying cations and anions | Test-tube reactions, flame tests, adding NaOH and dilute acid | Observations: colour, precipitate, gas, flame colour | Give the observation that identifies each ion, and the ionic equation |
| 5 | Distillation of a product | Simple distillation with still head and condenser | Boiling point range of the distillate | Why the thermometer bulb sits level with the side arm |
| 6 | Tests for alcohol, aldehyde, alkene and carboxylic acid | Tollens’ or Fehling’s, bromine water, sodium carbonate | Observations for each test | Why Tollens’ must be freshly prepared, why warming is needed |
| 7 | Rate by an initial-rate method | Measuring cylinder or gas syringe, stopwatch, graph of volume against time | Volume or mass at fixed times, initial gradient | How to find the initial rate from a tangent |
| 8 | Measuring the EMF of an electrochemical cell | Two half cells, salt bridge, high-resistance voltmeter | EMF to 0.01 V | Why a high-resistance voltmeter, why not a standard ammeter |
| 9 | pH changes in weak and strong acid–base titrations | pH meter or data logger, dropwise addition near the end point | pH to 0.1, volume to 0.1 cm³ | Sketch the titration curve and explain the shape |
| 10 | Preparing a pure organic solid and a pure organic liquid | Vacuum filtration, recrystallisation, melting point, separating funnel | Melting point range, yield, boiling point | Why the melting point is compared with a data book value |
| 11 | Identifying transition metal ions | Adding NaOH and ammonia in excess to solutions | Colour of solution and precipitate, solubility in excess | Explain why the precipitate dissolves in excess ammonia |
| 12 | Separation by thin-layer chromatography | Spotting, developing in a solvent, locating spots | Rf value to 2 d.p. | Why the baseline is drawn in pencil, what an Rf value shows |
All 12 AQA Required Practicals: Expert Exam Technique Guide
📚 How to get the most from this guide
Work through a past AQA Paper 3 question on a Required Practical first, then come back here to check your answer against the mark-scoring phrases. Don’t try to read it all at once — use the jump links below to go straight to the RPs your paper has targeted recently. For every RP, focus on the why column in the procedure table and the direction of error in the common mistakes section — these two areas are where A* students pull ahead.
RP 01: Make up a volumetric solution and carry out a simple acid–base titration
📋 Procedure — What You Do and WHY
| What you do | Why this step matters (examiner answer) |
|---|---|
| 1. Weigh the solid accurately by difference on a balance | Weighing by difference eliminates systematic error from any solid stuck to the weighing boat — the mass used is exactly the difference between the two readings |
| 2. Dissolve fully in distilled water, transfer via funnel to a volumetric flask, rinsing beaker, rod and funnel into the flask | Rinsing ensures no solute is lost — omitting this means your standard solution is less concentrated than calculated |
| 3. Add distilled water to just below the graduation mark, then dropwise to the bottom of the meniscus at eye level | Eye level prevents parallax error. Dropwise addition near the mark prevents overshooting the volume |
| 4. Stopper and invert several times to mix thoroughly | Ensures uniform concentration throughout the flask — poor mixing gives inconsistent titre results |
| 5. Rinse the burette with the solution it will hold; fill and clear the air bubble below the tap | An air bubble below the tap fills with solution during the titration, giving a titre that reads too high |
| 6. Pipette 25.0 cm3 of solution into a conical flask rinsed with distilled water only; add indicator | Rinsing the flask with distilled water (not the solution) does not affect the moles of analyte present. Rinsing with the solution would add extra moles and give a false titre |
| 7. Run a rough titration, then repeat to concordant titres (within 0.10 cm3); mean the concordant titres only | The rough titre establishes the approximate end-point so you can slow down in time to get a precise result. Concordant titres confirm reproducibility |
⚠ Common Exam Errors — Where Marks Are Lost
Funnel left in the burette. Solution in the funnel can drip in after a reading, increasing the apparent volume delivered. Remove the funnel before reading.
Wrong indicator for the titration type. Use methyl orange for strong acid – weak base; phenolphthalein for weak acid – strong base. The indicator’s colour-change range must fall on the steep section of the pH curve.
Averaging non-concordant titres. Only average titres within 0.10 cm3 of each other. Including the rough titre or outliers gives an inaccurate mean.
🔎 Worked Example
25.0 cm3 of NaOH needs 23.50 cm3 of 0.100 mol dm−3 HCl.
n(HCl) = 0.100 × (23.50 ÷ 1000) = 2.35 × 10−3 mol
HCl : NaOH = 1:1, so n(NaOH) = 2.35 × 10−3 mol
c(NaOH) = 2.35 × 10−3 ÷ (25.0 ÷ 1000) = 0.0940 mol dm−3
⭐ The Mark-Scoring Insight
RP 02: Measurement of an enthalpy change
📋 Procedure — What You Do and WHY
| What you do | Why this step matters (examiner answer) |
|---|---|
| 1. Measure a known volume of solution into a polystyrene cup with a lid; record temperature every 30 s for 2–3 min to establish a baseline | The baseline allows you to extrapolate back to the mixing time to find the true ΔT, correcting for heat lost during the reaction |
| 2. At a recorded time, add the second reactant and stir continuously | Stirring ensures even temperature distribution — without it, the thermometer reads a local value, not the bulk temperature |
| 3. Keep recording temperature every 30 s for several minutes | Enough data points after mixing are needed to draw a reliable cooling line for extrapolation |
| 4. Plot temperature vs time; extrapolate the cooling line back to the moment of mixing to find corrected ΔT | Extrapolation corrects for heat lost to surroundings while the reaction proceeds — without it, ΔH is underestimated |
| 5. Use c = 4.18 J g−1 K−1 and the mass of solution to calculate q; identify the limiting reagent for n | Using the mass of the solution (not just one reagent) is essential — all the solution absorbs the heat |
⚠ Common Exam Errors — Where Marks Are Lost
Not using a lid or insulation. Heat loss to surroundings makes ΔT too small, so ΔH is underestimated (less negative). Always use a polystyrene cup with a lid.
Reading the highest recorded temperature instead of extrapolating. The true maximum is higher than the recorded peak because heat is already being lost as the reaction proceeds. Extrapolation gives the correct ΔT.
Using the mass of one reagent only. The entire solution absorbs the heat energy. Use the total mass of the reaction mixture.
🔎 Worked Example
50.0 g solution, ΔT = 5.0 °C, c = 4.18 J g−1 K−1
q = 50.0 × 4.18 × 5.0 = 1045 J
n(limiting reagent) = 0.0050 mol
ΔH = −1045 ÷ 0.0050 = −209 000 J mol−1 = −209 kJ mol−1
⭐ The Mark-Scoring Insight
RP 03: Investigate how the rate of a reaction changes with temperature
📋 Procedure — What You Do and WHY
| What you do | Why this step matters (examiner answer) |
|---|---|
| 1. Measure a fixed volume of Na2S2O3 solution into a conical flask on a paper cross; warm to chosen temperature in a water bath and record the temperature | Controlling all variables except temperature is essential for a valid investigation. The water bath ensures the solution is at the correct temperature before timing begins |
| 2. Add a fixed volume of HCl and start the timer immediately | Starting the timer at the moment of mixing ensures you measure the full reaction time |
| 3. Look down through the solution; stop the timer when the cross can no longer be seen | Cloudy sulfur precipitate blocks the view of the cross — this is the fixed point of comparison across all temperatures |
| 4. Repeat across at least 5 temperatures; keep all volumes and concentrations constant | Changing only one variable (temperature) makes the investigation a fair test |
| 5. Calculate rate ∝ 1/t and plot against temperature | 1/t is proportional to rate; a steeper curve at higher temperatures demonstrates the Arrhenius relationship |
⚠ Common Exam Errors — Where Marks Are Lost
Subjective end-point judgement. The same person should judge every run using the same cross, flask and depth of solution. Different observers see the end-point differently.
Temperature drifting during the experiment. Record temperature at the start and end of each run and use the mean. The mixture cools during timing, especially at high temperatures.
Plotting t instead of 1/t. Plotting time gives a curve that falls with temperature. Plotting 1/t gives a curve that rises — this correctly represents rate increasing with temperature.
🔎 Worked Example
At 40 °C the cross disappears after 50 s.
Rate ∝ 1/t = 1/50 = 0.020 s−1
At 50 °C: time = 25 s, rate = 0.040 s−1
Rate doubles for a 10 °C rise — consistent with Arrhenius behaviour.
⭐ The Mark-Scoring Insight
RP 04: Test-tube reactions to identify cations and anions
📋 Procedure — What You Do and WHY
| What you do | Why this step matters (examiner answer) |
|---|---|
| 1. Test for carbonate first: add dilute acid — effervescence and limewater turns milky confirms CO32− | Carbonate gives false positives with Ba2+ and Ag+ — it must be removed by acidification before testing for sulfate and halide |
| 2. Test for sulfate: acidify with HCl, then add BaCl2(aq) — white precipitate of BaSO4 confirms SO42− | Acidification first destroys any remaining carbonate. The white BaSO4 precipitate is insoluble in acid — this distinguishes it from BaCO3 |
| 3. Test for halides: acidify with dilute HNO3, then add AgNO3(aq) | HNO3 is used (not HCl) because HCl would introduce Cl− ions, giving a false white precipitate. Precipitate colours: Cl− white, Br− cream, I− yellow |
| 4. Test for NH4+: add NaOH and warm gently — pungent gas turns damp red litmus blue confirms ammonia | NH3 is alkaline and turns moist red litmus blue. The gas must be tested while still damp — dry litmus does not respond |
| 5. Test for Group 2 cations: add NaOH — white precipitate (hydroxide) confirms M2+ | Group 2 hydroxides are white and relatively insoluble. More soluble going down the group: Mg(OH)2 least soluble, Ba(OH)2 most soluble |
⚠ Common Exam Errors — Where Marks Are Lost
Testing for sulfate before removing carbonate. Carbonate also precipitates with Ba2+, giving a false positive for sulfate. Always acidify to remove carbonate first.
Using HCl to acidify before the silver nitrate test. HCl introduces Cl− ions which produce a white AgCl precipitate — a false positive for chloride. Use dilute HNO3 only.
Forgetting to confirm halide identity with ammonia. Add dilute then concentrated NH3: AgCl dissolves in dilute NH3; AgBr dissolves only in concentrated NH3; AgI is insoluble in both.
🔎 Worked Example
Unknown solution gives: white precipitate with BaCl2 (after acidification) — confirms SO42−.
White precipitate with AgNO3 (after HNO3) dissolves in dilute NH3 — confirms Cl−.
Pungent gas with NaOH turns litmus blue — confirms NH4+.
Ion present: NH4+, SO42−, Cl−
⭐ The Mark-Scoring Insight
RP 05: Distillation of a product from a reaction
📋 Procedure — What You Do and WHY
| What you do | Why this step matters (examiner answer) |
|---|---|
| 1. Place the reaction mixture and anti-bumping granules in a round-bottomed flask | Anti-bumping granules provide nucleation sites for smooth, even boiling — without them, the mixture can superheat and boil violently |
| 2. Fit a still head with the thermometer bulb level with the side-arm; connect a Liebig condenser sloping downwards | The thermometer bulb must be at the side-arm to read the temperature of the vapour entering the condenser. Too high or too low gives the wrong boiling point |
| 3. Connect cooling water counter-current: in at the bottom, out at the top | Counter-current flow keeps the condenser full of cold water, maximising cooling efficiency. Never seal the apparatus — pressure builds up |
| 4. Heat gently with a water bath or electric heater — never a naked flame | Organic liquids are flammable. A water bath provides gentle, controllable, safe heating |
| 5. Collect the fraction distilling within the boiling range of the product | The correct boiling range ensures you collect the pure product, not solvent or higher-boiling impurities |
⚠ Common Exam Errors — Where Marks Are Lost
Thermometer bulb in the wrong position. The bulb must sit level with the side-arm of the still head — not dipping into the liquid (reads too high) and not above the side-arm (reads too low).
Water flowing in the wrong direction. Water enters at the bottom and leaves at the top so the condenser stays full. Reversed flow leaves the top of the condenser uncooled.
Not distilling the aldehyde as it forms. If the aldehyde stays in the reaction mixture with excess oxidising agent, it is oxidised further to a carboxylic acid. Continuous removal by distillation is the purpose of this practical.
🔎 Worked Example
Ethanal (CH3CHO) boils at 20 °C — collect the fraction below 25 °C.
Ethanol boils at 78 °C — any fraction above 70 °C is likely unreacted ethanol or higher-boiling material.
A distinct fraction at ~20 °C confirms the aldehyde has been separated successfully.
⭐ The Mark-Scoring Insight
RP 06: Tests for alcohol, aldehyde, alkene and carboxylic acid
📋 Procedure — What You Do and WHY
| What you do | Why this step matters (examiner answer) |
|---|---|
| 1. Test for alkene: add bromine water — orange decolourises to colourless | Br2 undergoes electrophilic addition across the C=C double bond. The orange colour disappears as the dibromo compound forms |
| 2. Test for carboxylic acid: add sodium carbonate solution — effervescence and limewater turns milky (CO2) | Only carboxylic acids are acidic enough to release CO2 from carbonate. Phenols do not react with Na2CO3 |
| 3. Test for primary/secondary alcohol: warm with acidified K2Cr2O7 — orange to green indicates oxidation occurred | Tertiary alcohols are not oxidised — the solution stays orange. Primary alcohols give aldehyde/acid; secondary give ketone |
| 4. Test for aldehyde (Tollens’): warm gently in a water bath with Tollens’ reagent — silver mirror forms | Aldehydes reduce Ag+ to Ag(s). Ketones cannot do this — no silver mirror. Must be warmed gently, not boiled |
| 5. Test for aldehyde (Fehling’s): warm gently in a water bath — blue to brick-red precipitate | Cu2+ (blue) is reduced to Cu+ (brick-red Cu2O precipitate). Ketones do not reduce Fehling’s solution |
⚠ Common Exam Errors — Where Marks Are Lost
Heating Tollens’ or Fehling’s over a direct flame. These must be warmed gently in a water bath. Direct heat can decompose Tollens’ reagent and prevents the clean silver mirror from forming.
Confusing aldehyde with carboxylic acid. Both have C=O. But only aldehyde gives a silver mirror with Tollens’; only carboxylic acid releases CO2 with Na2CO3.
Saying bromine water tests for C=O. Bromine water tests for C=C (alkene). Aldehydes do bleach bromine water too, but this is not the standard test — use Tollens’ or Fehling’s for aldehydes.
🔎 Worked Example
Unknown compound X decolourises bromine water → contains C=C (alkene present).
Does not react with Na2CO3 → not a carboxylic acid.
Does not give silver mirror with Tollens’ → not an aldehyde.
Conclusion: X is an alkene.
⭐ The Mark-Scoring Insight
RP 07: Measuring rate by an initial-rate method and by continuous monitoring
📋 Procedure — What You Do and WHY
| What you do | Why this step matters (examiner answer) |
|---|---|
| 1. Clock method: mix reagents (e.g. H2O2, KI, thiosulfate, starch) and start the timer | The thiosulfate immediately reduces any I2 formed back to I−. Only when the thiosulfate is exhausted does I2 accumulate and turn starch blue-black — a sudden, reproducible endpoint |
| 2. Record time until the sudden colour change; rate ∝ 1/t | 1/t represents the initial rate because only a small, fixed amount of reaction has occurred — concentrations are approximately unchanged from their initial values |
| 3. Repeat changing one reagent concentration at a time to find order with respect to each | Changing one variable at a time allows the order with respect to each reactant to be determined independently |
| 4. Continuous monitoring: follow a property (gas volume, mass loss or absorbance) at regular intervals throughout the reaction | Plotting property vs time gives a curve whose gradient equals the rate. The rate decreases as reactants are used up |
| 5. Draw tangents to the concentration–time curve to find instantaneous rates | The gradient of the tangent at any point gives the rate at that moment. Tangent at t=0 gives the initial rate |
⚠ Common Exam Errors — Where Marks Are Lost
Gas escaping before the bung is fitted. Any gas produced before sealing is not measured, underestimating the rate. Add the last reactant and stopper the flask in one smooth movement.
No cotton wool plug in the mass-loss method. Use a loose cotton wool plug so gas escapes (and is detected as mass loss) but spray droplets do not — otherwise lost liquid exaggerates the mass change.
Confusing order from initial-rate data. If doubling [A] quadruples the rate, the order is 2 (rate ∝ [A]2). If doubling [A] doubles the rate, the order is 1. If rate is unchanged, the order is 0.
🔎 Worked Example
Experiment 1: [A] = 0.10 mol dm−3, rate = 0.020 mol dm−3 s−1
Experiment 2: [A] = 0.20 mol dm−3, rate = 0.080 mol dm−3 s−1
Rate quadruples when [A] doubles → rate ∝ [A]2
Order with respect to A = 2
⭐ The Mark-Scoring Insight
RP 08: Measuring the EMF of an electrochemical cell
📋 Procedure — What You Do and WHY
| What you do | Why this step matters (examiner answer) |
|---|---|
| 1. Set up two half-cells — metal rod in its salt solution. Clean electrodes with emery paper | Oxide coatings on the metal surface increase resistance and give a lower, unreliable EMF. Emery paper removes the oxide layer |
| 2. Connect the solutions with a salt bridge (filter paper soaked in KNO3 solution) | The salt bridge completes the electrical circuit by allowing ion flow between half-cells while preventing the solutions mixing. KNO3 is used because K+ and NO3− do not react with most electrode solutions |
| 3. Connect electrodes to a high-resistance voltmeter and record the EMF | A high-resistance voltmeter draws almost no current, so the cell is not discharging. This allows measurement of the maximum potential difference (the EMF) |
| 4. For standard measurements: use 1.00 mol dm−3 solutions at 298 K | Standard electrode potentials are defined at 298 K and 1.00 mol dm−3 concentration. Deviating from these conditions gives non-standard EMF values |
| 5. Investigate concentration: replace 1.00 mol dm−3 with lower concentrations; record EMF | According to Le Chatelier’s principle, reducing [Cu2+] in the Cu half-cell shifts equilibrium to produce more Cu2+, making the electrode less positive — the EMF decreases |
⚠ Common Exam Errors — Where Marks Are Lost
Using an ordinary (low-resistance) voltmeter. Current flows, the cell discharges, and the reading falls continuously. A high-resistance voltmeter is essential for measuring true EMF.
Wrong salt bridge electrolyte. Use KNO3, not KCl — chloride ions could precipitate AgCl if silver half-cells are used, blocking the bridge and stopping the circuit.
Not cleaning the electrodes. Oxide layers act as resistors and reduce the measured EMF below the theoretical value — always clean with emery paper before use.
🔎 Worked Example
E°(Cu2+/Cu) = +0.34 V E°(Zn2+/Zn) = −0.76 V
E°cell = +0.34 − (−0.76) = +1.10 V
Copper is the positive electrode (cathode); zinc is oxidised (anode).
If [Cu2+] is reduced to 0.001 mol dm−3: EMF falls below +1.10 V.
⭐ The Mark-Scoring Insight
RP 09: How pH changes during weak-acid and weak-base titrations
📋 Procedure — What You Do and WHY
| What you do | Why this step matters (examiner answer) |
|---|---|
| 1. Calibrate the pH meter with buffer solutions of known pH before starting | An uncalibrated pH meter gives systematically wrong readings — calibration is always the first step and is always worth a mark |
| 2. Place acid in a beaker with the calibrated pH probe; add base from a burette in small portions, recording pH after each addition | Small portions give a smooth curve with enough data points to identify the steep section accurately |
| 3. Add smaller portions (0.10–0.25 cm3) near the equivalence point where pH changes fastest | The steep section spans only a small volume range — large additions would jump over the equivalence point |
| 4. Continue past the equivalence point; plot pH vs volume of base added | Data beyond the equivalence point confirms the shape of the upper curve and allows the steep section to be clearly identified |
| 5. Read key features: equivalence point (midpoint of steep section), half-neutralisation point (where pH = pKa), buffer region | At half-neutralisation: [acid] = [salt], so from Ka expression, [H+] = Ka, so pH = pKa — this is how pKa is measured experimentally |
⚠ Common Exam Errors — Where Marks Are Lost
Not calibrating the pH meter. This is the most common single-mark loss in this practical. Always state: calibrate with buffers of known pH before use.
Reading the equivalence point at pH 7. For weak acid–strong base: equivalence point is above pH 7 (the salt is alkaline due to hydrolysis). For strong acid–weak base: equivalence is below pH 7.
Choosing the wrong indicator. The indicator’s colour-change range must fall on the steep section of the curve. Weak acid–strong base: use phenolphthalein (changes pH 8.2–10.0). Strong acid–weak base: use methyl orange (changes pH 3.1–4.4).
🔎 Worked Example
Ethanoic acid (Ka = 1.8 × 10−5) titrated with NaOH.
pKa = −log(1.8 × 10−5) = 4.74
At half-neutralisation (VNaOH = 12.5 cm3): pH = 4.74
Equivalence point (VNaOH = 25.0 cm3): pH ≈ 8.9 (above 7 — alkaline salt)
Correct indicator: phenolphthalein
⭐ The Mark-Scoring Insight
RP 10: Prepare a pure organic solid and a pure organic liquid
📋 Procedure — What You Do and WHY
| What you do | Why this step matters (examiner answer) |
|---|---|
| 1. Recrystallisation: dissolve the crude solid in the minimum volume of hot solvent | Using excess solvent keeps the product dissolved on cooling, reducing yield. The minimum volume ensures maximum crystallisation on cooling |
| 2. Filter the hot solution through a pre-heated funnel to remove insoluble impurities | Filtering hot prevents premature crystallisation in the funnel. A pre-heated funnel prevents the solution cooling too quickly |
| 3. Cool slowly to allow crystals to form; soluble impurities remain in solution | Slow cooling gives larger, purer crystals. Fast cooling traps impurities within the crystal lattice |
| 4. Filter under reduced pressure (Büchner funnel), wash with a little cold solvent, and dry | Cold solvent dissolves impurities but not the product (which is far less soluble at low temperature). Warm solvent would redissolve the product |
| 5. Check purity by melting point: compare with literature value; impure samples melt lower and over a wider range | A sharp, accurate melting point confirms purity. A depressed or broad range indicates impurities are still present |
⚠ Common Exam Errors — Where Marks Are Lost
Using too much hot solvent. The product stays dissolved on cooling, so yield drops significantly. Use the minimum volume that just dissolves the solid when hot.
Washing crystals with warm solvent. Warm solvent will dissolve (and lose) some of the purified product. Always wash with a small volume of cold solvent.
Comparing melting points incorrectly. A pure substance melts sharply (narrow range, e.g. 1–2 °C). An impure substance melts over a wider range and at a lower temperature than the literature value.
🔎 Worked Example
Literature melting point of aspirin: 135 °C.
Sample A: melts 133–135 °C (sharp) → pure.
Sample B: melts 128–133 °C (broad range) → impure (impurities present lower the melting point and broaden the range).
⭐ The Mark-Scoring Insight
RP 11: Test-tube reactions to identify transition metal ions
📋 Procedure — What You Do and WHY
| What you do | Why this step matters (examiner answer) |
|---|---|
| 1. Add NaOH(aq) dropwise to the unknown solution; observe precipitate colour | Adding dropwise allows you to see the initial precipitate before checking for redissolution in excess — the precipitate colour is the key identifier |
| 2. Add NaOH in excess; observe whether the precipitate dissolves | Cr3+ forms a grey-green precipitate that dissolves in excess NaOH (amphoteric hydroxide) to give a dark green solution. All others are insoluble in excess NaOH |
| 3. Repeat with ammonia solution dropwise, then in excess | Cu(OH)2 dissolves in excess NH3 to give deep blue [Cu(NH3)4]2+ — a definitive test for Cu2+. Cr3+ hydroxide dissolves in excess NH3 to give a violet solution |
| 4. Record observations promptly, especially for Fe2+ | Fe(OH)2 is green but oxidises quickly to brown Fe(OH)3 on standing in air. Record the initial green colour immediately |
⚠ Common Exam Errors — Where Marks Are Lost
Adding NaOH all at once. You need to add dropwise first to see the precipitate form, then in excess to test for redissolution. All at once means you might miss the initial precipitate colour.
Observing Fe2+ too late. The green Fe(OH)2 precipitate oxidises to brown Fe(OH)3 in air. Record the colour immediately on adding NaOH — if you wait, it looks like Fe3+.
Confusing Cr3+ and Fe3+. Both give precipitates with NaOH, but only Cr3+ dissolves in excess NaOH (dark green) and in excess NH3 (violet). Fe3+ is insoluble in excess of both.
🔎 Worked Example
Ion colour summary:
Cu2+: blue precipitate with NaOH; dissolves deep blue in excess NH3
Fe2+: green precipitate (NaOH); insoluble in excess; browns in air
Fe3+: brown precipitate (NaOH); insoluble in excess
Cr3+: grey-green precipitate (NaOH); dissolves dark green in excess; dissolves violet in excess NH3
Mn2+: pale brown precipitate (NaOH); darkens in air; insoluble in excess
⭐ The Mark-Scoring Insight
RP 12: Separation of species by thin-layer chromatography (TLC)
📋 Procedure — What You Do and WHY
| What you do | Why this step matters (examiner answer) |
|---|---|
| 1. Draw a pencil baseline near the bottom of the TLC plate; spot samples as small, concentrated spots and let them dry | Ink dissolves in the mobile phase and travels up the plate, ruining the chromatogram. Pencil is inert. Small spots give well-defined, easy-to-measure separations |
| 2. Add solvent to the tank to a depth below the baseline; stand the plate in the tank and cover it | If the solvent is above the baseline, the spots dissolve directly into the bulk solvent and do not separate. The covered tank saturates the atmosphere with solvent vapour, giving reproducible Rf values |
| 3. Allow solvent to rise by capillary action; remove plate before solvent reaches the top; mark the solvent front immediately in pencil | The solvent front position is needed to calculate Rf. Mark it immediately — it evaporates and becomes invisible within seconds |
| 4. Reveal colourless spots under UV light or with a locating agent (e.g. iodine or ninhydrin); measure distances from baseline | UV light shows fluorescent compounds; locating agents react chemically with the spots to make them visible. Measure from the baseline to the centre of each spot |
| 5. Calculate Rf for each spot and compare with reference standards | Rf is constant for a given compound in a given solvent system at a given temperature. Comparison with references identifies unknowns |
⚠ Common Exam Errors — Where Marks Are Lost
Drawing the baseline in ink. Ink runs with the solvent, contaminating the plate and giving meaningless results. Always use pencil.
Solvent level above the baseline. The sample spots are submerged and dissolve into the bulk solvent instead of migrating up the plate. The solvent level must always be below the pencil baseline.
Not covering the tank. An unsaturated atmosphere means solvent evaporates from the plate as it rises, changing the rate of movement and giving non-reproducible Rf values.
🔎 Worked Example
Spot travels 2.4 cm from baseline; solvent front travels 6.0 cm.
Rf = 2.4 ÷ 6.0 = 0.40
Reference compound A: Rf = 0.40 in same solvent → spot is compound A.
Rf is always between 0 and 1 and is constant for the same compound, solvent and conditions.